citysys-flowserver/flow/thermometer.js
2024-04-13 20:29:31 +02:00

220 lines
No EOL
6.4 KiB
JavaScript

exports.id = 'thermometer';
exports.title = 'Thermometer';
exports.group = 'Worksys';
exports.color = '#5CB36D';
exports.version = '1.0.3';
exports.output = ["red", "white", "blue"];
exports.author = 'Rastislav Kovac';
exports.icon = 'thermometer-three-quarters';
exports.readme = `# Getting temperature values for RVO. In case of LM, you need device address. In case of unipi, evok sends values, in case thermometer is installed`;
const instanceSendTo = {
debug: 0,
tb: 1,
dido_controller: 2
}
//read temperature - frequency
let timeoutMin = 5;//minutes
var path = require('path');
var log4js = require("log4js");
log4js.configure({
appenders: {
errLogs: { type: 'file', filename: path.join(__dirname + "/../", 'err.txt') },
monitorLogs: { type: 'file', compress:true, daysToKeep: 2, maxLogSize: 1048576, backups: 1, keepFileExt: true, filename: path.join(__dirname + "/../", 'monitor.txt') },
console: { type: 'console' }
},
categories: {
errLogs: { appenders: ['console', 'errLogs'], level: 'error' },
monitorLogs: { appenders: ['console', 'monitorLogs'], level: 'trace' },
//another: { appenders: ['console'], level: 'trace' },
default: { appenders: ['console'], level: 'trace' }
}
});
const errLogger = log4js.getLogger("errLogs");
const logger = log4js.getLogger();
const monitor = log4js.getLogger("monitorLogs");
//logger.debug("text")
//monitor.info('info');
//errLogger.error("some error");
const { promisifyBuilder, makeMapFromDbResult } = require('./helper/db_helper');
const dbSettings = TABLE("settings");
let temperatureAddress = "";
async function loadSettings()
{
//todo global FLOW.OMS_edgeName is making problem, so we load it here as well, it should not be
let responseSettings = await promisifyBuilder(dbSettings.find());
temperatureAddress = responseSettings[0]["temperature_adress"];
}
loadSettings();
exports.install = function(instance) {
const { exec } = require('child_process');
const { sendNotification, ERRWEIGHT } = require('./helper/notification_reporter');
let startRead;
let dataToTb;
let counter = 0;
let edgeName = "";
logger.debug(exports.title, "installed");
instance.on("close", function(){
clearInterval(startRead);
})
const start = function() {
try {
if(FLOW.OMS_controller_type === "unipi")
{
clearInterval(startRead);
return;
}
if(temperatureAddress === "") throw "gettemperature: temperatureAddress is not defined";
logger.debug("FLOW.OMS_temperature_adress", FLOW.OMS_temperature_adress);
exec(`owread -C ${temperatureAddress}/temperature`, (error, stdout, stderr) => {
edgeName = FLOW.OMS_edgeName;
if(edgeName !== "")
{
if(error)
{
if(FLOW.OMS_brokerready == undefined)
{
logger.debug("gettemparature - FLOW.OMS_brokerready is undefined");
setTimeout(function(){
start();
}, 3000);
return;
}
if(FLOW.OMS_brokerready)
{
//sendNotification("start", edgeName, ERRWEIGHT.WARNING, "Thermometer is not responding", {"Error": error}, instanceSendTo.tb, instance, "thermometer");
sendNotification("start", edgeName, "thermometer_is_not_responding", {}, {"Error": error}, instanceSendTo.tb, instance, "thermometer");
}
let status = "NOK";
dataToTb = {
[edgeName]: [
{
"ts": Date.now(),
"values": {
"status": status
}
}
]
}
monitor.info("Thermometer is not responding", error, FLOW.OMS_brokerready);
// instance.send(instanceSendTo.tb, dataToTb); // poslat stav nok do tb, ak to handluje dido_controller ??
instance.send(instanceSendTo.dido_controller, {status: "NOK-thermometer"});
}
else parseData(stdout);
}
else
{
monitor.info("gettemperature: edgeName is not defined", FLOW.OMS_edgeName);
setTimeout(function(){
start();
}, 3000);
return;
}
//instance.send({"Temp":stdout,"stderr":stderr,"err":error});
});
}
catch(err) {
errLogger.error(exports.title, err);
}
}
const parseData = function(data) {
data = parseFloat(data);
logger.debug("gettemperature", data);
if(!isNaN(data)) {
if(counter > 290)
{
instance.send(instanceSendTo.debug, "[Get temperature component] - temperature data are comming again from RVO after more than 1 day break");
//sendNotification("parseData", edgeName, ERRWEIGHT.NOTICE, "Thermometer is working again", "", instanceSendTo.tb, instance, "thermometer");
if(FLOW.OMS_brokerready) sendNotification("parseData", edgeName, "thermometer_is_responding_again", {}, "", instanceSendTo.tb, instance, "thermometer");
}
logger.debug("gettemperature", data);
const values = {
"temperature": Number(data.toFixed(2)),
"status": "OK"
}
dataToTb = {
[edgeName]: [
{
"ts": Date.now(),
"values":values
}
]
}
instance.send(instanceSendTo.tb, dataToTb);
instance.send(instanceSendTo.dido_controller, values);
counter = 0;
} else {
counter++;
monitor.info("gettemperature err", counter, data);
//ked je problem 1 den
let day = 24 * 60 / timeoutMin;
if ( counter > day && counter < day + 2 ) {
//sendNotification("parseData", edgeName, ERRWEIGHT.WARNING, "Thermometer receives invalid data", "", instanceSendTo.tb, instance, "thermometer");
sendNotification("parseData", edgeName, "thermometer_sends_invalid_data", {}, "", instanceSendTo.tb, instance, "thermometer");
instance.send(instanceSendTo.debug, "[Get temperature component] - no temperature data from RVO for more than 1 day");
instance.send(instanceSendTo.dido_controller, {status: "NOK-thermometer"});
}
}
}
setTimeout(function(){
start();
}, 15000);
startRead = setInterval(start, timeoutMin * 1000 * 60);
};